@Article{ee.2023.029749,
AUTHOR = {Jingxiao Han, Chuanzhao Zhang, Lu Wang, Zengjun Chang, Qing Zhao, Ying Shi, Jiarui Wu, Xiangfei Kong},
TITLE = {Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump},
JOURNAL = {Energy Engineering},
VOLUME = {120},
YEAR = {2023},
NUMBER = {9},
PAGES = {1991--2011},
URL = {http://www.techscience.com/energy/v120n9/53703},
ISSN = {1546-0118},
ABSTRACT = {For heating systems based on electricity storage coupled with solar energy and an air source heat pump (ECSA),
choosing the appropriate combination of heat sources according to local conditions is the key to improving
economic efficiency. In this paper, four cities in three climatic regions in China were selected, namely Nanjing in
the hot summer and cold winter region, Tianjin in the cold region, Shenyang and Harbin in the severe cold winter
region. The levelized cost of heat (LCOH) was used as the economic evaluation index, and the energy consumption
and emissions of different pollutants were analyzed. TRNSYS software was used to simulate and analyze the system
performance. The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system
parameters. The results showed that ECSA system had an excellent operation effect in cold region and hot summer
and cold winter region. Compared with ECS system, the system energy consumption, and the emission of different
pollutants of ECSA system can be reduced by a maximum of 1.37 times. In cold region, the initial investment in an
air source heat pump is higher due to the lower ambient temperature, resulting in an increase in the LOCH value of
ECSA system. After the LOCH value of ECSA system in each region was optimized, the heating cost of the system
was reduced, but also resulted in an increase in energy consumption and the emission of different pollutant gases.},
DOI = {10.32604/ee.2023.029749}
}