TITLE = {Simplified Calculation of Flow Resistance of Suspension Bridge Main Cable Dehumidification System},
JOURNAL = {Fluid Dynamics \& Materials Processing},
VOLUME = {17},
YEAR = {2021},
NUMBER = {6},
PAGES = {1195--1211},
URL = {http://www.techscience.com/fdmp/v17n6/44449},
ISSN = {1555-2578},
ABSTRACT = {To calculate the flow resistance of a main cable dehumidification system, this study considers the air flow in the main cable as the flow in a porous medium, and adopts the Hagen–Poiseuille equation by using average hydraulic radius and capillary bundle models. A mathematical derivation is combined with an experimental study to obtain a semi-empirical flow resistance formula. Additionally, Fluent software is used to simulate the flow resistance across the main cable relative to the experimental values. Based on the actual measured results for a Yangtze River bridge, this study verifies the semi-empirical formula, and indicates that it can be applied in actual engineering.},
DOI = {10.32604/fdmp.2021.011753}
}