@Article{hmt.20.26,
AUTHOR = {Yangyang Tian
, Zhuo Chen , Qi Zhuang},
TITLE = {EFFECT OF GAS FLOW RATE ON SEPARATION EFFICIENCY AT  DIFFERENT SCALING SCALES OF CYCLONE SEPARATORS},
JOURNAL = {Frontiers in Heat and Mass Transfer},
VOLUME = {20},
YEAR = {2023},
NUMBER = {1},
PAGES = {1--11},
URL = {http://www.techscience.com/fhmt/v20n1/52388},
ISSN = {2151-8629},
ABSTRACT = {The cyclone separator has remarkable amplification effect, which is an important factor affecting its separation efficiency and pressure drop. The 
numerical simulation of Stairmand cyclone separators with cylinder diameters of 200, 280, 400, 480 and 600mm after geometric similarity amplification 
was carried out by ANSYS software. RSM model was used for gas phase and DPM model was used for particle phase. The results show that after the 
cyclone size is enlarged geometrically, the tangential velocity tends to increase with the increase of the cyclone barrel diameter at the same inlet gas 
velocity, which leads to the increase of turbulence energy in the internal flow field of the large size cyclone and the formation of local "eccentric 
circulation" in the cone section, and causes This leads to an increase in the tangential velocity, which leads to an increase in the turbulent energy in the 
internal flow field of the large-size cyclone, resulting in the formation of an eccentric ring flow in the cone section, and a tendency for "return flow" 
and "short-circuit flow" at the lower end of the overflow pipe. The numerical simulation of the particle motion and the experimental results of the 
separation efficiency both show that the separation efficiency of the Stairmand cyclone for particles of the same size decreases with the enlargement 
of the barrel diameter; the enlargement effect of the cyclone has little effect on the separation efficiency of particles above 10µm in diameter and a 
significant effect on the separation efficiency of particles below 10µm in diameter.},
DOI = {10.5098/hmt.20.26}
}