TY - EJOU
AU - Qi, Xin
AU - Shi, Xingtao
AU - Liu, Yingwen
TI - Modification and Experimental Verification of the Performance Improvement of Domestic Dehumidifiers
T2 - Frontiers in Heat and Mass Transfer
PY - 2024
VL - 22
IS - 6
SN - 2151-8629
AB - After optimizing the compressor design, condenser tube diameter, and tube row arrangement, air supply volumetric flow rate, and refrigerant charge of the domestic dehumidifier. The optimized design schemes were obtained from the original combinations by non-dominated sorting, and the optimized design schemes were experimentally verified under three environmental conditions according to the test method of T/CAS 342-2020 to obtain a complete idea of dehumidifier multi-component improvement. The results show that the dehumidifying capacity of Scheme 5 is slightly increased by 2.5% at 27°C/60% RH, and its energy factor is significantly increased by 24.6%. When the air supply volumetric flow rate was increased from 210 to 268 m3·h−1, the air supply temperature was reduced by 1.7°C, improving comfort. Under environmental conditions with higher dehumidification demand, i.e., at 35°C/90% RH, the energy factor of Scheme 4 can reach 4.3 L·kW−1·h−1, which is 34.4% higher than the original scheme, and the gap is further widened. The application of the 5 mm tube diameter condenser in dehumidifiers reduces the amount of refrigerant charge by 25.9%, reduces the cost by 7.5%, and strengthens the heat transfer effect and the homogeneity of the two-phase mixing, which shows the great application potential.
KW - Household dehumidifiers; performance improvement; dehumidification capacity; energy factor
DO - 10.32604/fhmt.2024.058959