@Article{hmt.v2.4.3006,
AUTHOR = {Channarong Wantha, Kriengkrai Assawamartbunlue},
TITLE = {THE IMPACT OF THE RESONANCE TUBE ON PERFORMANCE OF  A THERMOACOUSTIC STACK},
JOURNAL = {Frontiers in Heat and Mass Transfer},
VOLUME = {2},
YEAR = {2011},
NUMBER = {4},
PAGES = {1--8},
URL = {http://www.techscience.com/fhmt/v2n4/55768},
ISSN = {2151-8629},
ABSTRACT = {This paper presents a study of the impact of the resonance tube on performance of a thermoacoustic stack. The resonance tube is a key 
component of a standing-wave thermoacoustic refrigerator. The appropriated resonance tube’s length leads to an increase of performance of the 
stack in terms of the temperature difference. The results also indicate that the optimal operating frequency differs from the design based on the 
equation of a half-wavelength. The resonance tube length is elongated to compensate for some effects that occur in the resonance tube, 
especially when the stack is placed in the resonance tube. The relationship of these parameters is necessary to the design and measurement 
performance of the thermoacoustic refrigeration system.},
DOI = {10.5098/hmt.v2.4.3006}
}