@Article{hmt.v4.2.3001,
AUTHOR = {B. V. K. Reddy, Matthew Barry, John Li, Minking K. Chyu},
TITLE = {ENHANCEMENT OF THERMOELECTRIC DEVICE PERFORMANCE THROUGH INTEGRATED FLOW CHANNELS},
JOURNAL = {Frontiers in Heat and Mass Transfer},
VOLUME = {4},
YEAR = {2013},
NUMBER = {2},
PAGES = {1--7},
URL = {http://www.techscience.com/fhmt/v4n2/54900},
ISSN = {2151-8629},
ABSTRACT = {In this study, the thermoelectric performance of an integrated thermoelectric device (iTED) with rectangular, round end slots, and circular flow
channel designs applied to waste heat recovery for several hot stream flow rates has been investigated using numerical methods. An iTED is
constructed with p- and n-type semiconductor materials bonded to the surfaces of an interconnector with flow channels drilled through it. This
interconnector acts as an internal heat exchanger directing waste heat from the hot stream to thermoelectric elements. The quantity of heat extracted
from the waste heat source and the subsequent amount of electrical power generated P<sub>0</sub> from the iTED is increased significantly for the circular flow
channels, followed by round end slots and rectangular flow channels, respectively. At <i>Re</i> = 100, the round end slots and the circular flow channels
showed nearly 2.6 and 2.9 times increment in P<sub>0</sub>, and 1.5 and 1.65 times in η when compared to the rectangular flow channels values. Conversely,
when <i>Re</i> is increased from 100 to 500, the iTED with rectangular flow channels showed 2.67- and 1.6-fold improvement in P<sub>0</sub> and η, respectively.
However, the circular configurations showed 2.27- and 1.41-fold increases in P<sub>0</sub> and η values, respectively. Within the <i>Re</i> range studied, the inclusion
of flow channels’ pumping power in η calculations showed negligible effect. For an iTED with circular flow channels, an increase in a cold side
convective heat transfer coefficient h<sub>c</sub> resulted in an enhancement in P<sub>0</sub> and η values. Besides a hc effect, the heat loss to the ambient via convective
and radiation heat transfer exhibited an increase in P<sub>0</sub> and decrease in η.},
DOI = {10.5098/hmt.v4.2.3001}
}