@Article{mcb.2021.017503, AUTHOR = {Yang Li, Runxin Fang, Renyun Wang, Qiming Dai, Zhiyong Li, Genshan Ma}, TITLE = {Impact of Coronary Artery Curvature on the Longitudinal Stent Foreshortening: Real-World Observations}, JOURNAL = {Molecular \& Cellular Biomechanics}, VOLUME = {18}, YEAR = {2021}, NUMBER = {3}, PAGES = {119--122}, URL = {http://www.techscience.com/mcb/v18n3/43136}, ISSN = {1556-5300}, ABSTRACT = {Longitudinal stent foreshortening is a known phenomenon, however, the impact of coronary artery curvature on longitudinal stent foreshortening remains unclear. The aim of this study is to determine the impact of coronary artery curvature on the longitudinal stent foreshortening in the real-world scenarios. A total of 86 consecutive patients underwent coronary stent implantation were included in the present study. The degree of coronary artery curvature was defined as the length of the coronary artery curvature divided by the straight length. Longitudinal stent foreshortening was defined as the stent length after implantation divided by the stent length before implantation. The mean longitudinal foreshortening rate of coronary stents was about 94% in curved coronary arteries. Longitudinal stent foreshortening rate was positively correlated with the degree of coronary artery curvature (r = –0.86, P < 0.01). Coronary artery curvature is associated with significant longitudinal foreshortening of coronary stents, thus longitudinal foreshortening should be considered on deciding the stent length in curved coronary artery and a longer stent is usually needed in curved coronary artery.}, DOI = {10.32604/mcb.2021.017503} }