@Article{sdhm.2011.007.297,
AUTHOR = {K.N. Song},
TITLE = {Structural Behavior Analysis on a Small-scale PCHE Prototype under High-temperature Gas Loop Conditions},
JOURNAL = {Structural Durability \& Health Monitoring},
VOLUME = {7},
YEAR = {2011},
NUMBER = {4},
PAGES = {297--306},
URL = {http://www.techscience.com/sdhm/v7n4/35062},
ISSN = {1930-2991},
ABSTRACT = {The IHX (Intermediate Heat Exchanger) of a VHTR (Very High Temperature Reactor) transfers 950° heat generated from the VHTR to a hydrogen production plant. The Korea Atomic Energy Research Institute (KAERI) has manufactured a small-scale prototype of a PCHE (Printed Circuit Heat Exchanger) under consideration as a candidate of the IHX. In this study, as a part of high-temperature structural integrity evaluation of the small-scale PCHE prototype, we carried out a macroscopic structural behavior analysis including structural analysis modeling and thermal/elastic structural analysis under small-scale gas loop test conditions as a precedent study to a performance test. The results obtained in this study will be compared with the test results of the small-scale PCHE and also will be applied to the design of a medium-scale PCHE prototype.},