Abstract

Introduction: Explantation of the Interstim sacral neuromodulation (SNM) device is occasionally necessary. Removing the tined lead can put strain on the lead, resulting in a possible break and retained fragments. The Food and Drug Administration (FDA) released a notification regarding health consequences related to retained lead fragments. We describe a novel and safe surgical technique for removing the Interstim device and permanent lead.
Materials and methods: We searched the Manufacturer and User Facility Device Experience (MAUDE) database for complications related to tined lead removal and searched the database of a single surgeon at our institution. Our standardized technique for tined lead removal is as follows. An incision is made over the previous lead insertion site and the lead is isolated and externalized. The fibrous encapsulation is dissected off the lead to expose the tines and ensure the lead is free from adhesions. The lead is removed by wrapping it around a curved hemostat and turning it under tension. If the lead breaks, the incision is extended and dissection is carried down to the sacral body to remove all fragments.
Results: Twenty-eight patients had their tined lead removed between 2009 and 2015 after being in place a median of 2.00 years (IQR 1.32-3.32 years). One lead broke (3.6%) during removal over the 6 years using our standardized approach.
Conclusion: Permanent tined leads can break on removal and retained fragments can pose significant health consequences. Our technique standardizes the approach for removal and is safe and effective in our series.

Keywords

sacral neuromodulation, urinary incontinence, tined lead, retrained fragments, neuromodulation explantation

Cite This Article

APA Style
Sterling, M.E., Hartigan, S.M., Wein, A.J., Smith, A.L. (2016). Astandardized surgical technique for removal of the Interstim tined lead. Canadian Journal of Urology, 23(5), 8471–8475.
Vancouver Style
Sterling ME, Hartigan SM, Wein AJ, Smith AL. Astandardized surgical technique for removal of the Interstim tined lead. Can J Urology. 2016;23(5):8471–8475.
IEEE Style
M.E. Sterling, S.M. Hartigan, A.J. Wein, and A.L. Smith, “Astandardized surgical technique for removal of the Interstim tined lead,” Can. J. Urology, vol. 23, no. 5, pp. 8471–8475, 2016.



cc Copyright © 2016 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 174

    View

  • 132

    Download

  • 0

    Like

Share Link