Open Access
HOW I DO IT
Practical, cost-effective removal of Hem-o-lok Weck clip: a novel technique
1 University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
2 Department of Urology, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
Address correspondence to Braden Rolig, B.S., B.A., 806
Benton Drive, Apt 31, Iowa City, IA 52246 USA
Canadian Journal of Urology 2024, 31(5), 12019-12021.
Abstract
The Hem-o-lok Weck clip is part of a polymer locking ligation system often employed for hemostasis in surgical practices. Its use is routine in a wide array of surgical subspecialties. Surgeons have limited options in removing these clips when they are aberrantly positioned.Herein, we describe a novel, cost-effective approach for removing a Hem-o-lok clip using standard robotic instruments. This simple approach will allow surgeons to remove a Hem-o-lok clip precisely and quickly if it is not adequately placed.
During a routine robotic-assisted laparoscopic prostatectomy a Hem-o-lok Weck clip was noted to be in juxtaposition to the rectal wall, and it was deemed appropriate to remove it. Ultimately, the indwelling Prograsp forceps was moved from the right fourth arm position to the left arm position. This allowed the Prograsp forceps to compress the scissors in the right hand port, which was insufficient in cutting the hinge of the clip. This provided sufficient force to cut through the clip at its hinge with ease.
The Hem-o-lok Weck clip is used in various surgical specialties. It is occasionally placed suboptimally and requires removal. Given the challenge of finding and using the clip removal device, surgeons should be aware of this simple and cost-effective way of removing a Hem-o-lok clip if desired.
Keywords
Cite This Article

This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.