The ARTUS device: the first feasibility study in human cadavers

Tim A. Ludwig1,*, Philip Reiss1,*, Marco Wieland2, Andreas Becker1, Margit Fisch1, Felix K. Chun1, Roland Dahlem1

¹ Department of Urology, University Hospital Hamburg-Eppendorf, Germany
² Myopowers Medical Technologies SA, Lausanne, Switzerland
* both authors contributed equally to this work
Address correspondence to Dr. Tim A. Ludwig, Department of Urology, University Hospital Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg

Canadian Journal of Urology 2015, 22(6), 8100-8104.

Abstract

Introduction: The aim was to perform a feasibility study of the new artificial sphincter device ARTUS in human cadavers. ARTUS is a new electro-mechanical device, which may prevent urethral damage due to a new working principle which is to perform only sequential pressure on successive parts of the urethra.
Material and methods: The implantation of the ARTUS device was performed in six cadavers (3 males, 3 females) with different body mass indices. Subsequently the basic operation data (operation time, cuff size, length of wires, complication) were assessed.
Results: The implantation of the ARTUS device is performed easily by the same technique which is commonly used for the AMS 800 implantation. The mean operation time was 20 minutes. The mean cuff size was 4.5 cm in male and 6 cm in female cadavers. The average length of the wires was 12 cm. The necessary subcutaneous pouch had to be bigger than the space used for the tubes of the AMS 800 device. The study is limited by its preclinical setting.
Conclusions: Our results demonstrate that this new artificial urinary sphincter device can be easily implanted. The technical and surgical approaches are similar to those which are applied in the case of the AMS 800 device. Therefore experienced surgeons will be able to adapt their technique easily.

Keywords

artificial urinary sphincter, cadaver study, intrinsic sphincter deficiency, micro-electrical-mechanical system, stress urinary incontinence

Cite This Article

APA Style
Ludwig, T.A., Reiss, P., Wieland, M., Becker, A., Fisch, M. et al. (2015). The ARTUS device: the first feasibility study in human cadavers. Canadian Journal of Urology, 22(6), 8100–8104.
Vancouver Style
Ludwig TA, Reiss P, Wieland M, Becker A, Fisch M, Chun FK, et al. The ARTUS device: the first feasibility study in human cadavers. Can J Urology. 2015;22(6):8100–8104.
IEEE Style
T.A. Ludwig et al., “The ARTUS device: the first feasibility study in human cadavers,” Can. J. Urology, vol. 22, no. 6, pp. 8100–8104, 2015.



cc Copyright © 2015 The Author(s). Published by Tech Science Press.
This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 159

    View

  • 124

    Download

  • 0

    Like

Share Link