Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (9)
  • Open Access

    ARTICLE

    NUMERICAL SIMULATION OF TURBULENT FLOW IN A RECTANGULAR CHANNEL WITH PERIODICALLY MOUNTED LONGITUDINAL VORTEX GENERATORS

    Pankaj Sahaa, Gautam Biswasa,b,*

    Frontiers in Heat and Mass Transfer, Vol.2, No.3, pp. 1-5, 2011, DOI:10.5098/hmt.v2.3.3008

    Abstract Detailed flow structure in turbulent flows through a rectangular channel containing built-in winglet type vortex generators have been analyzed by means of solutions of the full Navier-Stokes equations using a Large-Eddy Simulation (LES) technique. The Reynolds number of investigation is 6000. The geometry of interest consists of a rectangular channel with a built-in winglet pair on the bottom wall with common-flow-down arrangement. The winglet pair induces streamwise longitudinal vortices behind it. The vortices swirl the flow around the axis parallel to the mainstream direction and disrupt the growth of thermal boundary layer entailing enhancement of heat transfer. The influence of… More >

  • Open Access

    ARTICLE

    PERFORMANCE ASSESSMENT AND EMPIRICAL CORRELATION IN A HEAT EXCHANGER SQUARE DUCT WITH DIAGONAL INSERTED GENERATORS

    Amnart Boonloi*

    Frontiers in Heat and Mass Transfer, Vol.5, pp. 1-12, 2014, DOI:10.5098/hmt.5.8

    Abstract A mathematical analysis of the heat transfer enhancement, thermal performance and flow configurations in a heat exchanger square duct with diagonal inserted plate vortex generators is presented. The 30o V–shaped baffles are modified and placed on the double sides of the thin plate or frame (with no plate) which inserted diagonally in the square duct. The effects of blockage ratio (b/H, BR), the pitch ratio (p/H, PR), flow direction (V–Downstream and V–Upstream) and configuration of inserting plate are investigated for Reynolds number based on the hydraulic diameter of the square duct, Dh, Re = 100 – 2000. The finite volume… More >

  • Open Access

    ARTICLE

    Numerical Study on the Effect of Vortex Generators on the Aerodynamic Drag of a High-Speed Train

    Tian Li1,2,*, Hao Liang1, Zerui Xiang2, Jiye Zhang1

    FDMP-Fluid Dynamics & Materials Processing, Vol.20, No.2, pp. 463-473, 2024, DOI:10.32604/fdmp.2023.043618

    Abstract A relatively high aerodynamic drag is an important factor that hinders the further acceleration of high-speed trains. Using the shear stress transport (SST) k-ω turbulence model, the effect of various vortex generator types on the aerodynamic characteristics of an ICE2 (Inter-city Electricity) train has been investigated. The results indicate that the vortex generators with wider triangle, trapezoid, and micro-ramp arranged on the surface of the tail car can significantly change the distribution of surface pressure and affect the vorticity intensity in the wake. This alteration effectively reduces the resistance of the tail car. Meanwhile, the micro-ramp vortex generator with its… More > Graphic Abstract

    Numerical Study on the Effect of Vortex Generators on the Aerodynamic Drag of a High-Speed Train

  • Open Access

    ARTICLE

    NUMERICAL INVESTIGATIONS ON HEAT TRANSFER AND FLOW STRUCTURE IN A CIRCULAR TUBE WITH VARIOUS SHAPES OF WINGLET VORTEX GENERATORS

    Amnart Boonloia, Withada Jedsadaratanachaib,*

    Frontiers in Heat and Mass Transfer, Vol.7, pp. 1-16, 2016, DOI:10.5098/hmt.7.22

    Abstract The numerical investigations on flow structure, heat transfer characteristic and thermal performance in a circular tube heat exchanger with various shapes of winglet vortex generators are reported. The rectangular winglet vortex generators (RWVG), delta winglet vortex generators (DWVG) and curve winglet vortex generators (CWVG) are inserted in the middle of the test tube on both downstream and upstream arrangements. The effects of blockage ratios; BR = 0.1 – 0.3, with single pitch ratio (PR = 1) and flow attack angle (α = 30o) on thermal performance are studied for the Reynolds numbers; Re = 100 – 2000. The numerical results… More >

  • Open Access

    ARTICLE

    THE EFFECTS OF WINGLET VORTEX GENERATOR POSITION IN RECTANGULAR-DUCT-TYPE SOLAR AIR HEATERS

    Boonchai Lertnuwat

    Frontiers in Heat and Mass Transfer, Vol.18, pp. 1-9, 2022, DOI:10.5098/hmt.18.1

    Abstract The aim of this work is to numerically investigate the effect of mounting winglet vortex generators on different positions in rectangular-duct-type air heaters. The two investigated positions were the absorber plate and the insulation plate, opposite to the absorber plate. Four shapes of winglet vortex generator, i.e. perforated rectangular winglet vortex generators (P-RWVG), rectangular winglet vortex generators (RWVG), perforated trapezoidal winglet vortex generators (P-TWVG) and trapezoidal winglet vortex generators (TWVG), were used. Results showed that heat-transfer capability would be better if the winglet vortex generators were mounted on the opposite insulation plate in the cases of P-RWVG, RWVG and P-TWVG. More >

  • Open Access

    ARTICLE

    Application of Vortex Generators to Remove Heat Trapped in Closed Channels

    Alim Al Ayub Ahmed1,*, Salim Oudah Mezan2, Binyamin3, Murtadha Doghiam Abdullah4, Elena Tesleva5, Linar G. Akhmetov6, Rustem Zalilov7, Mustafa M. Kadhim8,9,10, Abduladheem Turki Jalil11,12

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.1, pp. 15-24, 2023, DOI:10.32604/fdmp.2022.019922

    Abstract The utilization of vortex generators to increase heat transfer from cylinders installed inside a duct is investigated. In particular, a channel containing eight cylinders with volumetric heat sources is considered for different values of the Reynolds number. The effective possibility to use vortex generators with different sizes to increase heat transfer and, consequently, reduce the surface temperature of the cylinders is examined. Also, the amount of pressure drop inside the channel due to the presence of vortex generators is considered and compared with the cases without vortex generators. The results show that although the addition of generators increases the pressure… More >

  • Open Access

    ARTICLE

    Simulating the Turbulent Hydrothermal Behavior of Oil/MWCNT Nanofluid in a Solar Channel Heat Exchanger Equipped with Vortex Generators

    Rachid Maouedj1, Younes Menni2, Mustafa Inc3,4,*, Yu-Ming Chu5,6,*, Houari Ameur7, Giulio Lorenzini8

    CMES-Computer Modeling in Engineering & Sciences, Vol.126, No.3, pp. 855-889, 2021, DOI:10.32604/cmes.2021.014524

    Abstract Re-engineering the channel heat exchangers (CHEs) is the goal of many recent studies, due to their great importance in the scope of energy transport in various industrial and environmental fields. Changing the internal geometry of the CHEs by using extended surfaces, i.e., VGs (vortex generators), is the most common technique to enhance the efficiency of heat exchangers. This work aims to develop a new design of solar collectors to improve the overall energy efficiency. The study presents a new channel design by introducing VGs. The FVM (finite volume method) was adopted as a numerical technique to solve the problem, with… More >

  • Open Access

    ARTICLE

    CFD-Based Simulation and Analysis of Hydrothermal Aspects in Solar Channel Heat Exchangers with Various Designed Vortex Generators

    Mohamed Salmi1,2, Younes Menni3, Ali J. Chamkha4,5,*, Houari Ameur6, Rachid Maouedj7, Ahmed Youcef7

    CMES-Computer Modeling in Engineering & Sciences, Vol.126, No.1, pp. 147-173, 2021, DOI:10.32604/cmes.2021.012839

    Abstract The hydrothermal behavior of air inside a solar channel heat exchanger equipped with various shaped ribs is analyzed numerically. The bottom wall of the exchanger is kept adiabatic, while a constant value of the temperature is set at the upper wall. The duct is equipped with a flat rectangular fin on the upper wall and an upstream V-shaped baffle on the lower wall. Furthermore, five hot wall-attached rib shapes are considered: trapezoidal, square, triangular pointing upstream (type I), triangular pointing downstream (type II), and equilateral-triangular (type III) cross sections. Effects of the flow rates are also inspected for various Reynolds… More >

  • Open Access

    ARTICLE

    Numerical Study of the Intensity Correlation between Secondary Flow and Heat Transfer of Circle Tube-Finned Heat Exchanger with Vortex Generators

    Yong Guan1, Wanling Hu1, 2, *, Yun Zhang1, Kewei Song2, 3, Liangbi Wang2, 3

    CMES-Computer Modeling in Engineering & Sciences, Vol.123, No.1, pp. 237-256, 2020, DOI:10.32604/cmes.2020.09141

    Abstract The application of vortex generators in tube-finned heat exchangers is very universal. The vortex generators can generate secondary flow, and as we all know secondary flow can obviously strengthen heat transfer. To use vortex generators much more efficiently in the circle tube-finned heat exchangers, the intensity correlation study between secondary flow and heat transfer is needed. 22 different structures of circle tubefinned heat exchangers were numerically studied, including the plain fin cases and the cases with vortex generators. In addition, the influence of fin spacing, transverse and longitudinal tube pitch, heights and attack angle of vortex generators, positions of vortex… More >

Displaying 1-10 on page 1 of 9. Per Page