Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    Kinematic Analysis and Rock Mass Classifications for Rock Slope Failure at USAID Highways

    Ibnu Rusydy1,3,*, Nafisah Al-Huda1,2, M. Fahmi4, Naufal Effendi4

    Structural Durability & Health Monitoring, Vol.13, No.4, pp. 379-398, 2019, DOI:10.32604/sdhm.2019.08192

    Abstract Rock slope kinematic analysis and rock mass classifications has been conducted at the 17th km to 26th km of USAID (United States Agency for International Development) highway in Indonesia. This research aimed to examine the type of rock slope failures and the quality of rock mass as well. The scan-line method was performed in six slopes by using a geological compass to determine rock mass structure on the rock slope, and the condition of joints such as persistence, aperture, roughness, infilling material, weathering and groundwater conditions. Slope kinematic analysis was performed employing a stereographic projection. The rock slope quality and… More >

  • Open Access

    ABSTRACT

    Kinematic Analysis of Lumbar Spine Undergoing Extension and Dynamic Neural Foramina Cross Section Measurement

    Yongjie Zhang1, Boyle C. Cheng2, Changho Oh1, Jessica L. Spehar2, James Burgess3

    The International Conference on Computational & Experimental Engineering and Sciences, Vol.7, No.2, pp. 57-62, 2008, DOI:10.3970/icces.2008.007.057

    Abstract The spinal column plays a vital biomechanical role in the human body by providing structural support and facilitating motion. As degenerative changes occur in the spine, however, chronic pain can result which frequently forces patient to seek surgical treatment. Such treatments seek to address that pain, frequently by addressing both spinal motion and structural integrity. More >

  • Open Access

    ARTICLE

    Kinematic Analysis of Lumbar Spine Undergoing Extension and Dynamic Neural Foramina Cross Section Measurement

    Yongjie Zhang1, Boyle C. Cheng2, Changho Oh1, Jessica L. Spehar2, James Burgess3

    CMES-Computer Modeling in Engineering & Sciences, Vol.29, No.2, pp. 55-62, 2008, DOI:10.3970/cmes.2008.029.055

    Abstract The spinal column plays a vital biomechanical role in the human body by providing structural support and facilitating motion. As degenerative changes occur in the spine, surgical treatment may be necessary in certain instances. Such treatments seek to address pain, frequently through the restriction of spinal motion. Traditional spinal implant devices are designed to restrict the motion of a functional spinal unit (FSU) but newer device designs allow for semi-constrained motion such as spinal arthroplasty devices. In this study, a sequence of fluoroscopic imaging data was recorded during the flexibility protocol with an interspinous process spacer device placed at L2-L3.… More >

Displaying 1-10 on page 1 of 3. Per Page