Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (51)
  • Open Access

    ARTICLE

    Influence of Erosion Induced by NaCl on the Mechanical Performances of Alkali-Activated Mineral Admixtures

    Jing Yu1, Jie Ren2, Guangming Shen3, Weixiang Sun2, Hui Wang4,*

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.9, pp. 2385-2398, 2023, DOI:10.32604/fdmp.2023.027877

    Abstract In this paper, the influence of NaCl freeze-thaw (F-T) cycles and dry-wet (D-W) alternations on the flexural, compressive and bonding strengths of alkali-activated fly ash (FA) and a blast furnace slag powder (BFS) is investigated. The considered NaCl concentration is 3%. The effect of polypropylene fibers on the mechanical strengths is also examined. Scanning electron microscopy (SEM), thermogravimetry (TG) and X-ray diffraction (XRD) are selected to discern the mechanisms underpinning the NaCl-induced erosion. The obtained results indicate that the best results in terms of material resistance are obtained with admixtures containing 60% BFS and 40% FA in terms of mass… More >

  • Open Access

    ARTICLE

    Spray Effect on the Thermal Performances of a Dry Cooling Tower

    Zhe Geng1, Feng Feng1, Shuzhen Zhang1, Jie Li2, Chengwei Liu3, Yang Li4, Tiantian Liu4, Suoying He4,*

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.9, pp. 2289-2304, 2023, DOI:10.32604/fdmp.2023.026707

    Abstract Pre-cooling the inlet air of a dry cooling tower by means of a spray can improve the tower performance during periods of high temperature. To study the spray effect on the thermal performance of natural draft dry cooling towers (NDDCTs), in this study 3-D numerical simulations of such a process have been conducted using Fluent 16.2 (a two-way coupled Eulerian-Lagrangian approach). The considered NDDCT is 120 m high and only half system is simulated due to its structural symmetry. Three different spray strategies have been investigated at a typical crosswind speed of 4 m/s, which is the most frequent wind speed. The… More > Graphic Abstract

    Spray Effect on the Thermal Performances of a Dry Cooling Tower

  • Open Access

    ARTICLE

    EFFECT OF EVAPORATOR DIAMETERS ON PERFORMANCES OF A CUSTOM AIR WATER GENERATOR

    Mirmanto Mirmantoa,*, Syahrul Syahrula, Agung Tri Wijayantab

    Frontiers in Heat and Mass Transfer, Vol.20, pp. 1-5, 2023, DOI:10.5098/hmt.20.9

    Abstract A study to examine the effect of evaporator diameters on the performances of a custom air-water generator had been conducted in naturally room air temperatures. Performances in this study consisted of fresh water production, coefficient of performance, and total heat transfer from the air. The freshwater was attained from the dew that dropped from the evaporator walls. It was from water vapour in the air that condensed due to the low temperature of the evaporator walls. The evaporator which had dimensions of 285 mm x 12.7 mm x 480 mm was placed in an open box (top and bottom). It… More >

  • Open Access

    ARTICLE

    Influence of High-Robustness Polycarboxylate Superplasticizer on the Performances of Concrete Incorporating Fly Ash and Manufactured Sand

    Panpan Cao1,2, Xiulin Huang1,3,*, Shenxu Bao4, Jin Yang5,*

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.8, pp. 2041-2051, 2023, DOI:10.32604/fdmp.2023.027399

    Abstract Using ethylene glycol monovinyl polyoxyethylene ether, 2-acrylamido-2-methylpropane sulfonic acid (AMPS) and acrylic acid as the main synthetic monomers, a high robustness polycarboxylate superplasticizer was prepared. The effects of initial temperature, ratio of acid to ether, amount of chain transfer agent, and synthesis process on the properties of the superplasticizer were studied. The molecular structure was characterized by GPC (Gel Permeation Chromatography) and IR (Infrared Spectrometer). As shown by the results, when the initial reaction temperature is 15°C, the ratio of acid to ether is 3.4:1 and the acrylic acid pre-neutralization is 15%, The AMPS substitution is 10%, the amount of… More > Graphic Abstract

    Influence of High-Robustness Polycarboxylate Superplasticizer on the Performances of Concrete Incorporating Fly Ash and Manufactured Sand

  • Open Access

    ARTICLE

    Analysis of the Hydraulic Performances of a New Liquid Emitter Based on a Leaf Vein Concept

    Tianyu Xu, Zhouming Su, Yanru Su, Zonglei Li, Quanjie Chen, Shuteng Zhi, Ennan Zheng*, Kaili Meng

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.8, pp. 2147-2160, 2023, DOI:10.32604/fdmp.2023.025556

    Abstract The leaf-vein drip irrigation emitter is a new type of drip emitter based on a bionic structure able to support shunting, sharp turns, and increased dissipation. In the present work, the results of twenty-five tests executed in the framework of an orthogonal design strategy are presented in order to clarify the influence of the geometrical parameters of the flow channel on the hydraulic characteristics of such emitter. The corresponding flow index and head loss coefficient are determined through numerical simulations and model testing. The results show that the flow index of the flow channel is 0.4970∼0.5461, which corresponds to good… More >

  • Open Access

    ARTICLE

    Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers

    Guoqing Long1, Guogang Zhang1, Qi Zhang2, Cuilin Zhao2, Suoying He2,*, Fengzhong Sun2

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.7, pp. 1789-1801, 2023, DOI:10.32604/fdmp.2023.026559

    Abstract In recent years, water collecting systems, with the associated advantages of energy saving and noise reduction, have become the foundation for the development of a scheme to optimize the structure of cooling towers. To explore the feasibility of this approach for mechanical draft cooling towers, a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices (WCDs) for different water flow rates and wind speeds. The experimental results show that within the considered ranges of wind speed and water flow rate, the pressure drop of the different WCDs can vary significantly.… More > Graphic Abstract

    Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers

  • Open Access

    ARTICLE

    Simulation of the Production Performances of Horizontal Wells with a Fractured Shale Gas Reservoir

    Hongsha Xiao1, Ruihan Zhang2,*, Man Chen1, Cui Jing1, Shangjun Gao1, Chao Chen1, Huiyan Zhao1, Xin Huang2,*, Bo Kang3

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.7, pp. 1803-1815, 2023, DOI:10.32604/fdmp.2023.026143

    Abstract The production performances of a well with a shale gas reservoir displaying a complex fracture network are simulated. In particular, a micro-seismic cloud diagram is used to describe the fracture network, and accordingly, a production model is introduced based on a multi-scale flow mechanism. A finite volume method is then exploited for the integration of the model equations. The effects of apparent permeability, conductivity, Langmuir volume, and bottom hole pressure on gas well production are studied accordingly. The simulation results show that ignoring the micro-scale flow mechanism of the shale gas leads to underestimating the well gas production. It is… More > Graphic Abstract

    Simulation of the Production Performances of Horizontal Wells with a Fractured Shale Gas Reservoir

  • Open Access

    ARTICLE

    Modeling Date Palm Trunk Fibers (DPTF) Packed Bed Adsorption Performances for Cadmium Removal from Aqueous Wastewater

    Ahmad S. Awad1.*, Banan Hudaib2, Waid Omar2

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.6, pp. 1535-1549, 2023, DOI:10.32604/fdmp.2023.024300

    Abstract In this study, the potential of a low-cost bio-adsorbent, taken directly from Date Palm Trunk Fibers (DPTF) agricultural wastes, for cadmium ions removal from wastewaters is examined. The performances of this adsorbent are evaluated by building breakthrough curves at different bed heights and flow rates while keeping other parameters, such as the initial feed concentration, pH, and particle size, constant. The results indicate that the maximum cadmium adsorption capacity of DTPF can be obtained from the Thomas model as 51.5 mg/g with the most extended mass transfer zone of 83 min at the lowest flow rate at 5 ml/min. The… More > Graphic Abstract

    Modeling Date Palm Trunk Fibers (DPTF) Packed Bed Adsorption Performances for Cadmium Removal from Aqueous Wastewater

  • Open Access

    ARTICLE

    Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle

    Rachedi Khadraoui1, Latra Boumaraf1,*, Philippe Haberschill2

    FDMP-Fluid Dynamics & Materials Processing, Vol.19, No.5, pp. 1115-1128, 2023, DOI:10.32604/fdmp.2022.022674

    Abstract A theoretical investigation is presented about a double evaporator ejector refrigeration cycle (DEERC). Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger (IHX). The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure. Moreover, the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor. To assess accurately the influence of the IHX on the DEERC performance, a mathematical… More > Graphic Abstract

    Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle

  • Open Access

    ARTICLE

    Efficiency Performances of LVDC Supplies for Residential Building

    Anis Ammous*, Ammar Alsaedi, Ahmed N. M. Alahmadi, Fahad Alharbi, Kaiçar Ammous

    Computer Systems Science and Engineering, Vol.45, No.2, pp. 2171-2186, 2023, DOI:10.32604/csse.2023.029389

    Abstract The Low Voltage Direct Current (LVDC) architecture gives higher benefits over the classic low-voltage alternating current (LVAC) supply concept. LVDC has fewer energy conversion stages, is compatible with renewable energy sources, and is easier to integrate with accumulators. In this paper, an LVDC supply concept is proposed and compared with currently used conventional photovoltaic (PV) systems in terms of efficiency. The new LVDC photovoltaic system behavior is validated using LTspice modeling tool. The findings of this work prove that the concept of LVDC supply is highly attractive when the electricity produced by the photovoltaic is used onsite in the daytime.… More >

Displaying 11-20 on page 2 of 51. Per Page