Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (103)
  • Open Access

    ARTICLE

    Experimental and Numerical Study of the Key Non-Dimensional Geometrical Parameters on the Noise Level of Dry-Type Cast Resin Transformers

    Mahdi Soltanmohammadi1, Vahid Monfared2,*

    Sound & Vibration, Vol.53, No.5, pp. 177-198, 2019, DOI:10.32604/sv.2019.05811

    Abstract Dry-Type Cast Resin Distribution Transformers (CRT) is the secondgeneration of air-cooled distribution transformers where oil is replaced by resin for electrical insulation. CRT transformers may installed indoor adjacent to or near residential areas since they are clean and safe comparing to the conventional transformers. But, as it is obvious, noise discrepancy is intrinsically accompanied with all types of transformers and is inevitable for CRT transformers too. Minimization of noise level caused by such these transformers has biological and ergonomic importance. As it is known the core of transformers is the main source of the noise generation. In this paper, experimental… More >

  • Open Access

    ARTICLE

    Prediction of Outdoor Noise Propagation Induced By Single-Phase Power Transformers

    Xueyun Ruan1,2, Wei Huang1, Linke Zhang3, Yan Gao2,*

    Sound & Vibration, Vol.53, No.1, pp. 2-13, 2019, DOI:10.32604/sv.2019.04562

    Abstract Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems. Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations. In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies. The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency, which allows the single-phase power transformer to be simplified as incoherent point sources. An outdoor-coherent model… More >

  • Open Access

    ABSTRACT

    Research on Artificial Intelligence Method for Identification of Transformer Fault

    Ryuji Shioya and Hongjie Zheng

    The International Conference on Computational & Experimental Engineering and Sciences, Vol.22, No.4, pp. 195-195, 2019, DOI:10.32604/icces.2019.05008

    Abstract Oil-filled power transformers play an important role in the modern network system. Stability of power supply can be achieved by early detection of power transformer fault and continuous monitoring of equipment status. Transformers in operation are constantly affected by various types of stresses such as electrical, thermal and mechanical stress. Much attention is needed on maintenance of transformers in order to have fault free electric supply and to maximize the lifetime of a transformer. In recent years, Dissolved gas analysis (DGA) has been widely used for diagnostic fault of power transformers. Although DGA is an easier and simpler method for… More >

Displaying 101-110 on page 11 of 103. Per Page