Open Access iconOpen Access

ARTICLE

crossmark

Use of Implantable Cardioverter-Defibrillators in Congenital Heart Disease and Pediatric Patients: Results from the German National Registry for Congenital Heart Defects

Coralie Katharina Dicks1, Gerhard-Paul Diller1, Kristina Wasmer2, Paul C. Helm3,4, Ulrike M. M. Bauer3,4, Helmut Baumgartner1, Stefan Orwat1,#, Alicia Jeanette Fischer1,#,*

1 Department of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital of Muenster, Muenster, Germany
2 Department of Cardiology II-Electrophysiology, University Hospital of Muenster, Muenster, Germany
3 National Register for Congenital Heart Defects, Berlin, Germany
4 Deutsches Zentrum für Herz-Kreislauf-Forschung, Berlin, Germany

* Corresponding Author: Alicia Jeanette Fischer. Email: email
# Shared Authorship

Congenital Heart Disease 2020, 15(2), 117-125. https://doi.org/10.32604/CHD.2020.011520

Abstract

Background: Sudden cardiac death is a leading cause of death in patients with congenital heart disease (CHD). Risk stratification for implantable cardioverter defibrillators (ICD) remains difficult due to limited data about use and outcome of device therapy in CHD patients in larger community-based cohorts. Methods and results: Out of a dataset with more than 50,000 patients registered at the German National Register for Congenital Heart Defects, 109 patients (median age 35.5; IQR 23.75–46.00), 68 (62%) male) with an ICD were identified and were retrospectively analyzed. Although the number of implantations increased steadily throughout the investigated time interval from 2001 to 2015, only 0.2% of the CHD patients in the national register received an ICD. Indication for ICD implantation was secondary prevention in 84 patients (78%) and primary prevention in 24 patients (22%). 23 patients (21%) of the ICD patients received appropriate ICD therapy. 7 patients (6%) received an inappropriate ICD therapy. In 23 patients (21%) device complications were documented with a high number of lead fractures and insulation defects (n = 14, 13%). Conclusion: The current study investigates the clinical uptake and use of ICD therapy based on a large national registry for CHD patients. Despite a steady increase in the number of implanted devices, ICD uptake remains relatively low, particularly for primary prevention. The data suggests a potential reluctance in utilization of device therapy in this patient cohort for primary prevention. Selecting patients in whom benefits outweigh the risks associated with lifelong ICD therapy remains challenging.

Keywords


Cite This Article

Dicks, C. K., Diller, G., Wasmer, K., Helm, P. C., M., U. et al. (2020). Use of Implantable Cardioverter-Defibrillators in Congenital Heart Disease and Pediatric Patients: Results from the German National Registry for Congenital Heart Defects. Congenital Heart Disease, 15(2), 117–125.

Citations




cc This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 5336

    View

  • 3021

    Download

  • 1

    Like

Share Link