Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (33)
  • Open Access

    ARTICLE

    In Vitro Measurement and Calculation of Drag Force on Iliac Limb Stentgraft in a Compliant Arterial Wall Model

    A. Sinha Roy*, K. West, R. S. Rontala1, R. K. Greenberg2, R. K. Banerje1,‡

    Molecular & Cellular Biomechanics, Vol.4, No.4, pp. 211-226, 2007, DOI:10.3970/mcb.2007.004.211

    Abstract Interventional treatment of aortic aneurysms using endovascular stentgrafting is a minimally invasive technique. Following device implantation, transient drag forces act on the stentgraft. When the drag force exceeds the fixation force, complications like stentgraft migration, endoleaks and stentgraft failure occur. In such a scenario the device becomes unstable, causing concern over the long-term durability of endovascular repairs. The objective of this study is: 1) to measure the drag force on iliac limb stentgraft, having a distal diameter that is half the size of the proximal end, in an in vitro experiment; 2) to calculate the drag force using blood flow--compliant… More >

  • Open Access

    ARTICLE

    Inflation of An Artery Leading to Aneurysm Formation and Rupture

    J. S. Ren*

    Molecular & Cellular Biomechanics, Vol.4, No.1, pp. 55-66, 2007, DOI:10.3970/mcb.2007.004.055

    Abstract Formation and rupture of aneurysms due to the inflation of an artery with collagen fibers distributed in two preferred directions, subjected to internal pressure and axial stretch are examined within the framework of nonlinear elasticity. A two layer tube model with a fiber-reinforced composite based incompressible anisotropic hyperelastic constitutive material is employed to model the stress-strain behavior of the artery wall with distributed collagen fibers. The artery wall takes up a uniform inflation deformation, and there are no aneurysms in the artery under the normal condition. But an aneurysm may be formed in arteries when the stiffness of the fibers… More >

  • Open Access

    ARTICLE

    High-Fidelity Tetrahedral Mesh Generation from Medical Imaging Data for Fluid-Structure Interaction Analysis of Cerebral Aneurysms

    Yongjie Zhang1, Wenyan Wang1, Xinghua Liang1, Yuri Bazilevs2, Ming-Chen Hsu2, Trond Kvamsdal3, Reidar Brekken4, Jørgen Isaksen5

    CMES-Computer Modeling in Engineering & Sciences, Vol.42, No.2, pp. 131-150, 2009, DOI:10.3970/cmes.2009.042.131

    Abstract This paper describes a comprehensive and high-fidelity finite element meshing approach for patient-specific arterial geometries from medical imaging data, with emphasis on cerebral aneurysm configurations. The meshes contain both the blood volume and solid arterial wall, and are compatible at the fluid-solid interface. There are four main stages for this meshing method: 1) Image segmentation and geometric model construction; 2) Tetrahedral mesh generation for the fluid volume using the octree-based method; 3) Mesh quality improvement stage, in which edge-contraction, pillowing, optimization, geometric flow smoothing, and mesh cutting are applied to the fluid mesh; and 4) Mesh generation for the blood… More >

Displaying 31-40 on page 4 of 33. Per Page