Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (13)
  • Open Access

    ARTICLE

    Comparison of inflammatory microRNA expression in healthy and periodontitis tissues

    YOUNG HWA LEE1, HEE SAM NA1 , SO YEON JEONG1, SUNG HEE JEONG2 , HAE RYOUN PARK3 , JIN CHUNG1*

    BIOCELL, Vol.35, No.2, pp. 43-50, 2011, DOI:10.32604/biocell.2011.35.043

    Abstract MicroRNAs (miRNAs) are short RNA molecules that negatively regulate gene expression primarily by degrading target mRNA or inhibit the translation of protein product. Recently, many reports have shown the altered miRNA expression in various diseases. However, there are no reports on miRNA expression related to periodontitis. Thus, this study aimed to compare the miRNAs differentially expressed in healthy and chronic periodontitis tissues and to determine the miRNAs closely associated with chronic periodontitis. To find out the miRNAs differentially induced in healthy and chronic periodontitis tissues, miRNA microarray was carried out and the expression of miRNAs was confirmed by real-time PCR.… More >

  • Open Access

    ARTICLE

    Experimental Characterization of MCF-10A Normal Cells Using AFM: Comparison with MCF-7 Cancer Cells

    Moharam Habibnejad Korayem1,*, Zahra Rastegar2

    Molecular & Cellular Biomechanics, Vol.16, No.2, pp. 109-122, 2019, DOI:10.32604/mcb.2019.04706

    Abstract The mechanical properties of single cells have been recently identified as the basis of an emerging approach in medical applications since they are closely related to the biological processes of cells and human health conditions. The problem in hand is how to measure mechanical properties in order to obtain them more accurately and applicably. Some of the cell’s properties such as elasticity module and adhesion have been measured before using various methods; nevertheless, comprehensive tests for two healthy and cancerous cells have not been performed simultaneously. As a Nanoscale device, AFM has been used for some biological cells, however for… More >

  • Open Access

    ARTICLE

    Comparison of Right Ventricle Morphological and Mechanical Characteristics for Healthy and Patients with Tetralogy of Fallot: An In Vivo MRI-Based Modeling Study

    Dalin Tang1,*,2, Heng Zuo2,*, Chun Yang2, Zheyang Wu2, Xueying Huang3, Rahul H. Rathod4, Alexander Tang4, Kristen L. Billiar5, Tal Geva4

    Molecular & Cellular Biomechanics, Vol.14, No.3, pp. 137-151, 2017, DOI:10.3970/mcb.2017.014.137

    Abstract Patients with repaired tetralogy of Fallot (TOF) account for the majority of cases with late onset right ventricle failure. Comparing TOF patients with healthy people may provide information to address this challenge. Cardiac magnetic resonance (CMR) data were obtained from 16 TOF patients (patient group, PG) and 6 healthy volunteers (healthy group, HG). At begin-of-ejection, better patient group (n=5, BPG) stress was very close to HG stress (54.7±38.4 kPa vs. 51.2±55.7 kPa, p=0.6889) while worse patient group (n=11, WPG) stress was 84% higher than HG stress (p=0.0418). Stress may be used as an indicator to differentiate BPG patients from WPG… More >

Displaying 11-20 on page 2 of 13. Per Page