Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (3)
  • Open Access

    ARTICLE

    A NUMERICAL STUDY OF THE EFFECT OF A BELOW-WINDOW CONVECTIVE HEATER ON THE HEAT TRANSFER RATE FROM A COLD RECESSED WINDOW

    Patrick H. Oosthuizen*

    Frontiers in Heat and Mass Transfer, Vol.2, No.1, pp. 1-8, 2011, DOI:10.5098/hmt.v2.1.3004

    Abstract The convective heat transfer to a window below which is mounted a natural convective heater has been numerically studied. The flow has been assumed to be three-dimensional and steady and to involve regions of laminar and turbulent flow. Fluid properties have been assumed constant except for the density change with temperature which leads to the buoyancy forces. The solution has been obtained using a commercial cfd code. Results have been obtained for a Prandtl number of 0.7. The effects of changes in the flow variables on the window Nusselt number and on the flow and temperature distributions have been examined. More >

  • Open Access

    ARTICLE

    MODIFICATION OF PERFORATED PLATE IN FLUIDIZED-BED COMBUSTOR TO PROVIDE SUFFICIENT AIR SUPPLY IN THE COMBUSTION

    Erdiwansyah Erdiwansyaha,d , Mahidin Mahidinb, Husni Husinb, Muhammad Faisalc, Usman Usmanc, Muhtadin Muhtadinc, Asri Ganib,*, Rizalman Mamate

    Frontiers in Heat and Mass Transfer, Vol.18, pp. 1-6, 2022, DOI:10.5098/hmt.18.25

    Abstract The modification of the perforated plate applied in this study aims to provide sufficient air access into the combustion chamber. Burning experiments were carried out with three different types of fuel (such as palm kernel shell (PKS), oil palm midrib (OPM), and empty fruit bunches (EFB). The purpose of the experiment with the modification of the perforated plate is to investigate the combustion temperature and the rate of heat transfer in the boiler. The fluidized-bed combustor (FBC) combustion chamber is used as the combustion chamber. Experimental results were obtained at four different points using a Digital Thermometer with a thermocouple.… More >

  • Open Access

    ARTICLE

    Modeling of Heat Transfer and Steam Condensation Inside a Horizontal Flattened Tube

    M. Gh. Mohammed Kamil1,*, M. S. Kassim1, R. A. Mahmood2,3, L. AZ Mahdi4

    FDMP-Fluid Dynamics & Materials Processing, Vol.18, No.4, pp. 985-998, 2022, DOI:10.32604/fdmp.2022.018938

    Abstract This work investigates the steam condensation phenomena in an air-cooled condenser. The considered horizontal flattened tube has a 30 mm hydraulic diameter, and its length is a function of the steam quality with a limit value between 0.95 and 0.05. The mass flow rate ranges from 4 to 40 kg/m2.s with a saturated temperature spanning an interval from 40°C to 80°C. A special approach has been implemented using the Engineering Equation Solver (EES) to solve a series of equations for the two-phase flow pattern and the related heat transfer coefficients. A wavy-stratified structure of the two-phase flow has been found when… More >

Displaying 1-10 on page 1 of 3. Per Page