Open Access iconOpen Access

ARTICLE

crossmark

Numerical Simulation of the Seismic Response of a Horizontal Storage Tank Based on a SPH–FEM Coupling Method

Peilei Yan1,2,*, Endong Guo1,2, Houli Wu1,2, Liangchao Zhang1,2

1 Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin, 150080, China
2 Key Laboratory of Earthquake Disaster Mitigation, Ministry of Emergency Management, Harbin, 150080, China

* Corresponding Author: Peilei Yan. Email: email

(This article belongs to the Special Issue: Recent Advances in Computational Methods for Performance Assessment of Engineering Structures and Materials against Dynamic Loadings)

Computer Modeling in Engineering & Sciences 2024, 139(2), 1655-1678. https://doi.org/10.32604/cmes.2023.044760

Abstract

A coupled numerical calculation method combining smooth particle hydrodynamics (SPH) and the finite element method (FEM) was implemented to investigate the seismic response of horizontal storage tanks. A numerical model of a horizontal storage tank featuring a free liquid surface under seismic action was constructed using the SPH–FEM coupling method. The stored liquid was discretized using SPH particles, while the tank and supports were discretized using the FEM. The interaction between the stored liquid and the tank was simulated by using the meshless particle contact method. Then, the numerical simulation results were compared and analyzed against seismic simulation shaking table test data to validate the method. Subsequently, a series of numerical models, considering different liquid storage volumes and seismic effects, were constructed to obtain time history data of base shear and top center displacement, which revealed the seismic performance of horizontal storage tanks. Numerical simulation results and experimental data showed good agreement, with an error rate of less than 18.85%. And this conformity signifies the rationality of the SPH–FEM coupling method. The base shear and top center displacement values obtained by the coupled SPH–FEM method were only 53.3% to 69.1% of those calculated by the equivalent mass method employed in the current code. As the stored liquid volume increased, the seismic response of the horizontal storage tank exhibited a gradual upward trend, with the seismic response increasing from 73% to 388% for every 35% increase in stored liquid volume. The maximum von Mises stress of the tank and the supports remained below the steel yield strength during the earthquake. The coupled SPH–FEM method holds certain advantages in studying the seismic problems of tanks with complex structural forms, particularly due to the representation of the flow field distribution during earthquakes by involving reservoir fluid participation.

Keywords


Cite This Article

APA Style
Yan, P., Guo, E., Wu, H., Zhang, L. (2024). Numerical simulation of the seismic response of a horizontal storage tank based on a SPH–FEM coupling method. Computer Modeling in Engineering & Sciences, 139(2), 1655-1678. https://doi.org/10.32604/cmes.2023.044760
Vancouver Style
Yan P, Guo E, Wu H, Zhang L. Numerical simulation of the seismic response of a horizontal storage tank based on a SPH–FEM coupling method. Comput Model Eng Sci. 2024;139(2):1655-1678 https://doi.org/10.32604/cmes.2023.044760
IEEE Style
P. Yan, E. Guo, H. Wu, and L. Zhang "Numerical Simulation of the Seismic Response of a Horizontal Storage Tank Based on a SPH–FEM Coupling Method," Comput. Model. Eng. Sci., vol. 139, no. 2, pp. 1655-1678. 2024. https://doi.org/10.32604/cmes.2023.044760



cc This work is licensed under a Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • 350

    View

  • 158

    Download

  • 0

    Like

Share Link