Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (36)
  • Open Access

    ARTICLE

    CFD-Based Optimization of Hot Primary-Air Pipe Networks in Power Plant Milling Systems

    Qingyun Yan1, You Li2, Yuanhong Zhu3, Kui Cheng3, Xueli Huang3, Cong Qi3, Xuemin Ye2,*

    FDMP-Fluid Dynamics & Materials Processing, Vol.16, No.3, pp. 623-636, 2020, DOI:10.32604/fdmp.2020.09669

    Abstract A hot primary-air pipe system is the bridge connecting an air-preheater with a coal mill in power generation stations. The effective geometrical configuration of the pipe network greatly affects the air flow distribution and consequently influences the safe and economic operation of milling systems in power stations. In order to improve the properties of the air flow, in the present work the SIMPLEC method is used to simulate numerically the flow field for the original layout of the system. As a result, the internal mechanisms influencing the uneven pressure drop in each branch are explored and three optimization schemes are… More >

  • Open Access

    ARTICLE

    Integrated Condition Monitoring of Large Captive Power Plants and Aluminum Smelters

    J.K. Mohanty1, A. Adarsh2, P.R. Dash1, K. Parida1, P.K. Pradhan1,*

    Sound & Vibration, Vol.53, No.5, pp. 223-235, 2019, DOI:10.32604/sv.2019.07737

    Abstract Condition monitoring is implementation of the advanced diagnostic techniques to reduce downtime and to increase the efficiency and reliability. The research is for determining the usage of advanced techniques like Vibration analysis, Oil analysis and Thermography to diagnose ensuing problems of the Plant and Machinery at an early stage and plan to take corrective and preventive actions to eliminate the forthcoming breakdown and enhancing the reliability of the system. Nowadays, the most of the industries have adopted the condition monitoring techniques as a part of support system to the basic maintenance strategies. Major condition monitoring technique they follow is Vibration… More >

  • Open Access

    ABSTRACT

    Development of On-line Structural Condition Monitoring System in Korean Nuclear Power Plant

    Jin-Ho Park1, Joon-Hyun Lee2

    The International Conference on Computational & Experimental Engineering and Sciences, Vol.13, No.4, pp. 65-66, 2009, DOI:10.3970/icces.2009.013.065

    Abstract The on-line structural integrity monitoring systems and the related techniques have been developed in Korean nuclear power plant for the purpose of Condition Based Maintenance(CBM). There are four different kinds of systems such as IVMS(Internal Vibration Monitoring System), LPMS(Loose Part Monitoring System), ALMS(Acoustic Leak Monitoring System), and RCP-VMS(Reactor Coolant Pump Vibration Monitoring system). The purpose of the IVMS is to monitor and diagnose the axial preload of the core support barrel and the abnormality of the motion of the fuel bundles inside the reactor pressure vessel. The LPMS is being operated to detect and alarm the presence of loose parts… More >

  • Open Access

    ABSTRACT

    Probabilistic Floor Response Spectrum of Nonlinear Nuclear Power Plant Structure using Latin Hypercube Sampling Method

    Heekun Ju, Hyung-Jo Jung*

    The International Conference on Computational & Experimental Engineering and Sciences, Vol.21, No.1, pp. 7-7, 2019, DOI:10.32604/icces.2019.05846

    Abstract Latin hypercube sampling (LHS) is widely applied to estimate a probabilistic floor response spectrum (FRS) of nonlinear nuclear power plant (NPP) structure. ASCE 4-16 Standards recommend that the minimum number of simulations should be larger than 30 when using LHS. Although this recommendation is commonly used for the minimum number of the simulation, there is no theoretical background. The variability of the estimations may exist according to the number of the simulation. Stated differently, the minimum number of the simulation may be varied depending on the characteristics of the problem (i.e., problem-dependent). In this context, the required sample size of… More >

  • Open Access

    ABSTRACT

    Numerical Investigation of Floor Response Spectrum Considering Nonlinear Behavior of Shear Walls in Nuclear Power Plants

    Hyung-Jo Jung, Heekun Ju

    The International Conference on Computational & Experimental Engineering and Sciences, Vol.21, No.1, pp. 6-6, 2019, DOI:10.32604/icces.2019.05761

    Abstract The floor response spectrum (FRS) of a nuclear power plant (NPP) structure considering nonlinear behavior of shear walls is numerically investigated. The Hysteretic Material from OpenSees program is applied to a lumped-mass model to consider the nonlinear hysteretic behavior of the element representing the shear wall. Parameters that determine the hysteretic behavior are changed to examine the effects of the parameters on the resulting FRS. The pinching effect, damage due to ductility and energy, and degraded unloading stiffness can be considered with changes in parameter values. The hysteretic behavior of the structure with different parameter values was analyzed. Elements in… More >

  • Open Access

    ARTICLE

    IoT Based Approach in a Power System Network for Optimizing Distributed Generation Parameters

    P. Shanmugapriya1, J. Baskaran2, C. Nayanatara1,*, D. P. Kothari3

    CMES-Computer Modeling in Engineering & Sciences, Vol.119, No.3, pp. 541-558, 2019, DOI:10.32604/cmes.2019.04074

    Abstract The objective of this paper is to provide a robust Virtual Power Plant (VPP) network collaborated with Internet of Things (IoT) which uses a conceptual model to integrate each device in the grid. Based on the functionality all the devices which are purely distributed within the grid are networked initially from residential units to substations and up to service data and demand centres. To ensure the trapping of the available power and the efficient transfer of Distributed Generation (DG) power to the grid Distribution Active Control (DAC) strategy is used. Synchronized optimization of DG parameter which includes DG size, location… More >

Displaying 31-40 on page 4 of 36. Per Page