Home / Advanced Search

  • Title/Keywords

  • Author/Affliations

  • Journal

  • Article Type

  • Start Year

  • End Year

Update SearchingClear
  • Articles
  • Online
Search Results (534)
  • Open Access

    ARTICLE

    An Evaluation to the Performance of Evacuated Tube Solar Heaters for Arid and Hot Areas

    Asaad H. Sayer1, Samah Hussein Kadhim1, Hameed B. Mahood2,*

    Energy Engineering, Vol.120, No.3, pp. 587-596, 2023, DOI:10.32604/ee.2023.025407

    Abstract Solar energy applications could be the best alternative to the conventional fuels for the purposes of domestic, water and space heating and some industries in the sunny, arid, and hot areas. In the present study, the performance of an evacuated tube solar heater for water heating for months of February and March was experimentally investigated. This was performed in a hot and arid area (Nasiriya City, South of Iraq). A solar heater with ten evacuated tube solar collectors with a capacity of 100 liter was used in the experiments. Each evacuated tube had a length of 1.8 m with an outside… More >

  • Open Access

    ARTICLE

    Research on Mixed Logic Dynamic Modeling and Finite Control Set Model Predictive Control of Multi-Inverter Parallel System

    Xiaojuan Lu, Mengqiao Chen, Qingbo Zhang*

    Energy Engineering, Vol.120, No.3, pp. 649-664, 2023, DOI:10.32604/ee.2023.025065

    Abstract Parallel connection of multiple inverters is an important means to solve the expansion, reserve and protection of distributed power generation, such as photovoltaics. In view of the shortcomings of traditional droop control methods such as weak anti-interference ability, low tracking accuracy of inverter output voltage and serious circulation phenomenon, a finite control set model predictive control (FCS-MPC) strategy of microgrid multi-inverter parallel system based on Mixed Logical Dynamical (MLD) modeling is proposed. Firstly, the MLD modeling method is introduced logical variables, combining discrete events and continuous events to form an overall differential equation, which makes the modeling more accurate. Then… More > Graphic Abstract

    Research on Mixed Logic Dynamic Modeling and Finite Control Set Model Predictive Control of Multi-Inverter Parallel System

  • Open Access

    ARTICLE

    Analysis of Temperature Rise Characteristics and Fatigue Damage Degree of ACSR Broken Strand

    Jun Zhang1, Xiaobin Li1, Long Zhao2,*, Zixin Li1, Shuo Wang1, Pan Yao1, Pengfei Dai2

    Energy Engineering, Vol.120, No.3, pp. 617-631, 2023, DOI:10.32604/ee.2022.024855

    Abstract In this paper, the research on ACSR temperature of broken strand and fatigue damage after broken strand is carried out. Conduct modeling and Analysis on the conductor through Ansoft Maxwell software. The distribution of magnetic force lines in the cross section of the conductor after strand breaking and the temperature change law of the conductor with the number of broken strands are analyzed. A model based on electromagnetic theory is established to analyze the distribution of magnetic lines of force in the cross section of the conductor after strand breaking and the temperature variation law of the conductor with the… More >

  • Open Access

    ARTICLE

    Identification Method for Users-Transformer Relationship in Station Area Based on Local Selective Combination in Parallel Outlier Ensembles Algorithm

    Yunlong Ma1, Junwei Niu2,*, Bo Xu3, Xingtao Song2, Wei Huang2, Guoqiang Sun2

    Energy Engineering, Vol.120, No.3, pp. 681-700, 2023, DOI:10.32604/ee.2023.024719

    Abstract In the power distribution system, the missing or incorrect file of users-transformer relationship (UTR) in low-voltage station area (LVSA) will affect the lean management of the LVSA, and the operation and maintenance of the distribution network. To effectively improve the lean management of LVSA, the paper proposes an identification method for the UTR based on Local Selective Combination in Parallel Outlier Ensembles algorithm (LSCP). Firstly, the voltage data is reconstructed based on the information entropy to highlight the differences in between. Then, the LSCP algorithm combines four base outlier detection algorithms, namely Isolation Forest (I-Forest), One-Class Support Vector Machine (OC-SVM),… More >

  • Open Access

    ARTICLE

    Optimization of Electricity Purchase and Sales Strategies of Electricity Retailers under the Condition of Limited Clean Energy Consumption

    Peng Liao1,*, Hanlin Liu1, Yingjie Wang2, Neng Liao3

    Energy Engineering, Vol.120, No.3, pp. 701-714, 2023, DOI:10.32604/ee.2022.024301

    Abstract In the process of my country’s energy transition, the clean energy of hydropower, wind power and photovoltaic power generation has ushered in great development, but due to the randomness and volatility of its output, it has caused a certain waste of clean energy power generation resources. Regarding the purchase and sale of electricity by electricity retailers under the condition of limited clean energy consumption, this paper establishes a quantitative model of clean energy restricted electricity from the perspective of power system supply and demand balance. Then it analyzes the source-charge dual uncertain factors in the electricity retailer purchasing and selling… More > Graphic Abstract

    Optimization of Electricity Purchase and Sales Strategies of Electricity Retailers under the Condition of Limited Clean Energy Consumption

  • Open Access

    ARTICLE

    Electric Vehicle Charging Capacity of Distribution Network Considering Conventional Load Composition

    Pengwei Yang1, Yuqi Cao2, Jie Tan2, Junfa Chen1, Chao Zhang1, Yan Wang1, Haifeng Liang2,*

    Energy Engineering, Vol.120, No.3, pp. 743-762, 2023, DOI:10.32604/ee.2023.024128

    Abstract At present, the large-scale access to electric vehicles (EVs) is exerting considerable pressure on the distribution network. Hence, it is particularly important to analyze the capacity of the distribution network to accommodate EVs. To this end, we propose a method for analyzing the EV capacity of the distribution network by considering the composition of the conventional load. First, the analysis and pretreatment methods for the distribution network architecture and conventional load are proposed. Second, the charging behavior of an EV is simulated by combining the Monte Carlo method and the trip chain theory. After obtaining the temporal and spatial distribution… More >

  • Open Access

    ARTICLE

    Stability Analysis and Control of DC Distribution System with Electric Vehicles

    Zhijie Zheng1, Song Zhang1, Xiaolei Zhang2, Bo Yang1, Fang Yan3, Xiaoning Ge3,*

    Energy Engineering, Vol.120, No.3, pp. 633-647, 2023, DOI:10.32604/ee.2022.024081

    Abstract The DC distribution network system equipped with a large number of power electronic equipment exhibits weak damping characteristics and is prone to low-frequency and high-frequency unstable oscillations. The current interpretation of the oscillation mechanism has not been unified. Firstly, this paper established the complete state-space model of the distribution system consisting of a large number of electric vehicles, characteristic equation of the distribution network system is derived by establishing a state-space model, and simplified reduced-order equations describing the low-frequency oscillation and the high-frequency oscillation are obtained. Secondly, based on eigenvalue analysis, the oscillation modes and the influence of the key… More >

  • Open Access

    ARTICLE

    Studies on Performance of Distributed Vertical Axis Wind Turbine under Building Turbulence

    Xin Sun1, Chi Zhang3, Yan Jia1,2,*, Shikang Sui1, Chong Zuo1, Xueqiang Liu1

    Energy Engineering, Vol.120, No.3, pp. 729-742, 2023, DOI:10.32604/ee.2022.023398

    Abstract As a part of the new energy development trend, distributed power generation may fully utilize a variety of decentralized energy sources. Buildings close to the installation location, besides, may have a considerable impact on the wind turbines’ operation. Using a combined vertical axis wind turbine with an S-shaped lift outer blade and Φ-shaped drag inner blade, this paper investigates how a novel type of upstream wall interacts with the incident wind at various speeds, the influence region of the turbulent vortex, and performance variation. The results demonstrate that the building’s turbulence affects the wind’s horizontal and vertical direction, as well… More > Graphic Abstract

    Studies on Performance of Distributed Vertical Axis Wind Turbine under Building Turbulence

  • Open Access

    ARTICLE

    Traceability Technology of DC Electric Energy Metering for On-Site Inspection of Chargers

    Hua Li1,*, Dezhi Xiong2,3, Zhi Wang2,3

    Energy Engineering, Vol.120, No.3, pp. 715-727, 2023, DOI:10.32604/ee.2022.022990

    Abstract The on-site inspection of high-power DC chargers results in new DC high-current measurement and DC energy traceability system requirements. This paper studies the traceability technology of electric energy value for automotive high-power DC chargers, including: (1) the traceability method of the built-in DC energy meter and shunt of the charger; (2) precision DC high current and small precision DC voltage output and measurement technology. This paper designs a 0.1 mA~600 A DC high current measurement system and proposes a 0.005 level DC power measurement traceability system. The uncertainty evaluation experiment of the DC power measurement calibration system and the high-power… More >

  • Open Access

    ARTICLE

    Comparative Analysis of Equal and Unequal Grounding Grid Configurations by Compression Ratio and Least Square Curve Fitting Techniques

    M. Soni*, Abraham George

    Energy Engineering, Vol.120, No.3, pp. 597-616, 2023, DOI:10.32604/ee.2023.021301

    Abstract The primary aim of the power system grounding is to safeguard the person and satisfying the performance of the power system to maintain reliable operation. With equal conductor spacing grounding grid design, the distribution of the current in the grid is not uniform. Hence, unequal grid conductor span in which grid conductors are concentrated more at the periphery is safer to practice than equal spacing. This paper presents the comparative analysis of two novel techniques that create unequal spacing among the grid conductors: the least-square curve fitting technique and the compression ratio technique with equal grid configuration for both square… More >

Displaying 191-200 on page 20 of 534. Per Page