Home / Journals / ENERGY / Online First / doi:10.32604/ee.2026.083896
Special Issues

Open Access

ARTICLE

Transient Thermo-Hydraulic Behavior of a Thermocline Thermal Energy Storage Tank: A CFD Investigation

Abdellah Idrissi1,*, Elbachir Abddaim2,3, Hicham El Mghari1, Rachid El Amraoui1, Siham Sakami4, Lahcen Boukhattem2,3, Brahim Addou1
1 Laboratory of Energy Engineering and Materials (LEEM), Faculty of Sciences and Technologies, Sultan Moulay Slimane University, Beni Mellal, Morocco
2 LMPEQ, National School of Applied Sciences, Safi, Morocco
3 EnR2E Laboratory, National Center for Studies and Research on Water and Energy, Cadi Ayyad University, Marrakesh, Morocco
4 L3G, Faculty of Science and Technology Cadi Ayyad University, Marrakesh, Morocco
* Corresponding Author: Abdellah Idrissi. Email: email

Energy Engineering https://doi.org/10.32604/ee.2026.083896

Received 13 April 2026; Accepted 16 June 2026; Published online 27 July 2026

Abstract

This study numerically investigates the influence of inlet–outlet arrangement on the thermo-hydraulic performance of a thermocline thermal energy storage (TES) tank using three-dimensional transient CFD simulations in ANSYS Fluent. Four different inlet–outlet configurations were analyzed under identical discharge conditions to evaluate their effects on thermal stratification, discharge efficiency, and internal flow behavior. The numerical model was developed using the continuity, momentum, and energy equations with the Boussinesq approximation and validated against reference experimental data with deviations below 5%. The results showed that the inlet–outlet arrangement significantly affects thermocline evolution and thermal mixing inside the storage tank. Among the investigated configurations, Configuration 2 exhibited the most favorable thermo-hydraulic behavior, improving thermal stratification and discharge efficiency by approximately 18%–22% compared with the baseline configuration because of reduced recirculation intensity and weaker thermal mixing. Although Configuration 2 produced a moderate increase in pressure drop and pumping power, the improved thermal performance justified the associated hydraulic penalty. The obtained findings indicate that relatively simple modifications in inlet–outlet positioning can improve thermocline preservation and thermal energy recovery in compact TES systems.

Keywords

Thermal energy storage; thermocline tank; thermal stratification; CFD; inlet–outlet arrangement; discharge efficiency